This is a list of the technical
specifications of the TNA 2000 hardware range.
Related Articles
Hardware Feature Comparison
TNA 2000 Hardware
Overview
Power Supply
All devices require a 12V-18V DC power
supply. The current required depends on the options used. The following
table shows the various options, and the power they consume. (These
numbers are measured using a 15V power supply)
CapeClock 32 / 128 / 256
|
Basic (no readers) |
160 mA |
|
Dim Backlighting |
+ 40 mA |
|
Bright Backlighting |
+ 100 mA |
|
Barcode reader |
+ 30 mA |
|
682-10 GSC Wiegand reader |
+ 60 mA |
|
30387 HID Wiegand reader |
+ 30 mA |
|
GSC Proximity reader |
+ 40 mA |
|
Keypad |
+ 5 mA |
|
Dallas Tag Reader |
+ 40 mA |
|
Fingerprint Reader - Identify |
+ 170 mA |
|
Fingerprint Reader - Verify |
+ 330 mA |
Example : Clock with 2 barcode readers,
and bright backlighting =
160 + 30 + 30 + 100 = 320 mA
CapeDoor 128 / 256
|
Basic (no readers) |
155 mA |
|
Barcode reader |
+ 30 mA |
|
682-10 GSC Wiegand reader |
+ 60 mA |
|
30387 HID Wiegand reader |
+ 30 mA |
|
GSC Proximity reader |
+ 40 mA |
|
Keypad |
+ 40 mA |
|
Dallas Tag Reader |
+ 40 mA |
|
Fingerprint Reader - Identify |
+ 170 mA |
|
Fingerprint Reader - Verify |
+ 330 mA |
Controller
|
Basic (no readers) |
70 mA |
|
Dim Backlighting |
+ 40 mA |
|
Bright Backlighting |
+ 100 mA |
Junction Box
Output Switch Ratings (Relay Ratings)
Check these ratings before attaching the
clocks to Sirens, or Electronic locks, or other external devices (via
the Relays).
|
|
DC Load |
AC Load |
|
Contact Rating |
28 W |
60 VA |
|
Maximum Switching Voltage |
150 V |
220 V |
|
Maximum Switching Current |
2 A |
1.25 A |
|
Maximum Carrying Current |
2 A |
2 A |
|