Hardware Specifications |
||||
|
|
Hardware |
|||
|
|
CLK32/128/256 |
Door128/256 |
Controller |
Junction Box |
|
Voltage Supply |
12-18Vdc |
12-18Vdc |
12-18Vdc |
12-18Vdc |
|
|
|
|
|
|
|
Current Consumption (Vdc = 15V) |
|
|
|
|
|
Basic (No Readers) |
70mA |
65mA |
70mA |
60mA |
|
Dim Backlighting |
+ 40mA |
|
+ 40mA |
|
|
Bright Backlighting |
+ 100mA |
|
+ 100mA |
|
|
Barcode Reader |
+ 30mA |
+ 30mA |
|
|
|
682-10 Wiegand Reader |
+ 60mA |
+ 60mA |
|
|
|
30387 Wiegand Reader |
+ 30mA |
+ 30mA |
|
|
|
Proximity/Dallas tag Reader |
+ 40mA |
+ 40mA |
|
|
|
Keypad |
+ 5 mA |
+ 5 mA |
||
|
All Outputs and Buzzer On |
+ 90mA |
+ 90mA |
+ 90mA |
|
|
Fingerprint Reader - identify |
+ 170mA |
|
|
|
|
Fingerprint Reader - verify |
+ 330mA |
|
|
|
|
|
|
|
|
|
|
Examples on Max Current Consumption |
|
|
|
|
|
Max Current (2 Barcode Readers) |
320mA |
215mA |
|
|
|
Max Current (1 Proximity Readers) |
300mA |
195mA |
|
|
|
Max Current (No Readers) |
|
|
260mA |
|
|
|
|
|
|
|
|
Output Switch Rating (Siren, Door Locks) |
DC Load |
AC Load |
|
|
|
Contact Rating |
28W |
60VA |
|
|
|
Max Switching Voltage |
150V |
220V |
|
|
|
Max Switching Current |
2A |
1.25A |
|
|
|
Max Carrying Current |
2A |
2A |
|
|
|
|
|
|
|
|
|
Daisy Chaining (Vdc = 15V) |
Max Distance |
|
|
|
|
Max Distance (individually powered) |
1Km |
|
|
|
|
Max Distance (shared power - Backlighting On) |
80m |
|
|
|
|
Max Distance (shared power - Backlighting Off) |
280m |
|
|
|